Framery Gradus Huddle soundproof pod on a US office floor

The huddle room that brings its own paperwork: Framery Gradus Huddle

Framery
Complete office pod
Huddle Most Requested Complete office pod
$ 27,216

Tell us your requirements

Trade terms for professionals and design studios

A pod is furniture right up until a building official asks what it is. Framery Gradus Huddle has an answer already on file: an ICC-ES evaluation report, ESR4445, issued against the acceptance criteria 519 for acoustic pods, with third-party test data and on-site manufacturing audits behind it. The line is drawn around the International Building, Fire and Mechanical Codes, listed to UL 962 as OSHA requires of workplace electrical equipment, and seismic tested to ASCE 7-16 with restraints a professional engineer can stamp for your address.

Inside, one to four people sit on two firm sofas rated at 600 pounds each, in a New Zealand wool blend specified as dirt and water repellent, around a wide table curved to let the far seat in. Speech drops 30 dB in Class A under ISO 23351-1. Airflow reads occupancy, temperature and humidity, scales to 203 CFM, then flushes the room faster once the meeting ends. Two presets sit on the eight-inch touchscreen: work mode puts up to 500 lux on the table, video mode up to 585 lux on the face — one lights the paper, the other lights the person on the far end of the call.

At 87.8 inches wide and only 49.7 deep it works as a wall as much as a room, which is how Framery draws it: a divider that hosts, placed inside an office neighborhood rather than against its perimeter, with corner lights outside reading green, yellow or red so nobody knocks. The Gradus line is assembled in Michigan, Framery's second plant after Finland, engineered around US and Canadian regulation. La Mercanti specifies it for American floors, and the evaluation report, the EPD and the GREENGUARD Gold certificate download straight from this page — so the compliance conversation opens already answered.

Technical information based on data declared by the manufacturer.

Collection: Framery Gradus Huddle
Manufacturer: Framery (Finland); Gradus line assembled in Michigan, USA
Type: smart soundproof huddle room and meeting pod for 1 to 4 people
Soundproofing: 30 dB speech level reduction, Class A (ISO 23351-1)
Ventilation: adaptive, up to 203 CFM (159 typical in use, 136 standby); reads occupancy, temperature and humidity; higher-speed refresh after use; manual override
Lighting: two 4000 K LED sources; up to 500 lux on the table top and 585 lux on the face in video mode; standard and video presets, manual adjustment
Controls: 8-inch touchscreen on the table; mmWave radar presence detection; exterior corner occupancy lights, green, yellow and red
Connectivity: built-in 4G with SIM and Wi-Fi 802.11 a/b/g/n/ac; over-the-air updates; bookable as a room, automated walk-in reservations, anonymous occupancy data in Framery Connect
Power: 38 W default, 96 W maximum, 13 W standby; 120 VAC 60 Hz, NEMA 5-15P plug; Essentials 4 power outlets and 2 USB-C PD 65 W; optional under-table outlets and LAN; 23 ft cord
Dimensions: 91.8 × 87.8 × 49.7 in with air filter housing; doorway 82.6 × 38 in, 180° swing, left or right handed; threshold 0.5 in; weight 1,102 lb
Table: birch plywood, 34.6 × 27.2 in, fixed height 28 in, 131 lb load; white, black anti-fingerprint, oak or walnut
Seating: two sofas 43.3 × 23 in, seat height 18.5 in, 600 lb load; 85% New Zealand wool and 15% polyamide, dirt and water repellent
Materials: powder-coated matte steel exterior panels, matte black aluminum frames, 0.16 + 0.16 in sound control laminated glass, light steel and PET acoustic chassis, recycled polyester interior panels, antistatic low loop pile carpet
Versions: Base, Essentials, Essentials+ with Framery Room Display
Compliance: UL 962; ICC-ES evaluation report ESR4445 against acceptance criteria 519; designed to IBC, IFC and IMC; seismic tested to ASCE 7-16 with PE-stampable restraints; compatible with fire sprinklers and notification devices; all electronics in the roof structure
Environment: UL GREENGUARD Gold; third-party verified EPD, LCA, HPD and Declare label published for the Gradus line; documentation contributing to LEED, BREEAM, SKA and WELL submissions; fully modular, every component replaceable; EcoVadis Gold; Certified Autism Resource by IBCCES
Accessories: rotating monitor arm for 24 to 27 in displays, privacy film, wooden or fabric wall panels, custom cushions, exterior tablet mount, reusable movability kit, standalone fire suppression

La Mercanti USA Llc — your partner for Italian design and contract supply.
Los Angeles, CA, USA · +1 855 335 8079 · info@lamercanti.us
Supply, quotes, specifications and project support across the United States and North America.

FAQ

Our building official asked what a pod is. What do we send?
The ICC-ES evaluation report, ESR4445, issued against the acceptance criteria 519 for acoustic pods. It carries verified third-party test data and on-site audits of the manufacturing process, which is what closes the question at plan review. Framery also works with local engineers and consultants who handle those conversations with inspectors and building officials.
We build in a seismic zone. What can actually be stamped?
The pods are seismic tested to ASCE 7-16 and designed for straightforward floor anchoring, and the seismic restraints can be PE stamped for your specific location and building design. That is the step that moves a pod out of the furniture schedule and into something a structural reviewer can sign.
Where do the electronics sit if sprinklers are involved?
All of them are in the roof structure, reachable regardless of how the pod is placed or whether sprinkler coverage is added over it. Gradus pods are compatible with fire sprinklers and notification devices, so a ceiling plan does not have to be redrawn around the room.
Can a pod work for people who find open offices overwhelming?
Framery holds the Certified Autism Resource designation from IBCCES, awarded after an expert board reviewed the product against competency areas for the needs of individuals with autism. In daily use that translates into a room the occupant sets: Class A acoustics, two lighting modes, airflow that adapts instead of running at one speed.
Where is the Gradus line assembled?
In Michigan, at Framery's second plant after the original factory in Finland, with the whole line engineered around US and Canadian regulations from the start. Delivery times are confirmed in writing at order confirmation.

Putting a huddle room in the middle of the floor

Five moves for placing Gradus Huddle where the conversations already happen, and clearing it with the building in one pass.

Follow the conversations
Watch for two weeks where the unscheduled syncs actually break out. That corner of the neighborhood is the site: the leftover strip along the perimeter is where a pod gets walked past.
Let it work as the wall
At 87.8 inches wide and 49.7 deep the pod divides a neighborhood while it hosts one. Drawn as architecture rather than dropped as furniture, it defines two zones instead of consuming one.
Fix the handedness early
The doorway runs 82.6 by 38 inches with a 180-degree swing over a half-inch threshold. Left-handed is standard and right-handed is available, and that single choice sets the circulation around the room.
Send one code packet
Evaluation report ESR4445, UL 962 listing, ASCE 7-16 seismic data and the published EPD travel together. One packet answers the building official, the fire reviewer and the sustainability lead in a single round.
Hand the schedule to the pod
The corner lights read green, yellow and red from across the floor, and stepping inside opens a walk-in reservation that syncs with the company calendar. Framery Connect reports how often the room is really used, with no personally identifiable data collected.