Blade System rows by Lamm laid out across a sloped lecture hall

Tighten Blade System by 2 3/8 in and gain a row in fifteen

Lamm

Dante Bonuccelli

Blade System
Blade System An icon of Italian design
From $ 9,900

Let's discuss your project

Trade terms for professionals and design studios

Seat count in a lecture hall is arithmetic, and the arithmetic is usually fixed before anyone picks the university classroom furniture. Blade System is unusual in publishing the one number that moves it. Lamm states that the system allows the distance between rows to be reduced by up to 2 3/8 in, which makes it possible to add one further row every fifteen in the same space — or, if the room is already full enough, to give that space back to circulation.

The dimensioned drawings carry the same figure twice over. A standard row runs at min. 20 in centre to centre; the compact row on the same sheet is drawn at 17 3/4 in. The difference is exactly the 2 3/8 in the catalogue claims, which means the compact layout is a drawn condition of the system and not a sales estimate.

Fifteen rows is not an abstract threshold. A hall of 300 seats laid out twenty to a row is fifteen rows, so the choice is worth roughly a full row of seats — the kind of number that decides whether a program fits a building. The depth each row occupies on the step stays at 35 1/2 in either way: what changes is the spacing along the row, not the tier.

Beyond university lecture rooms, Lamm declares the line for conference halls and auditoriums, and the study bench may also be supplied alone for a flat floor or an existing tier. A teacher's desk is built to the dimensions requested.

Let us know which finishes you'd like to explore

$ 180

Credited in full toward your purchase

FAQ

How many seats do we gain by tightening the spacing?

One row for every fifteen, in the same floor area. The manufacturer allows the distance between rows to be reduced by up to 2 3/8 in, taking a 20 in pitch down to the 17 3/4 in shown on the dimensioned drawing. Applied to a 300-seat hall at twenty seats per row, that is one additional row. The same reduction can be spent the other way, on wider circulation, if the seat count is already met.

How much depth does one row take on the tier?

35 1/2 in. That figure is independent of the pitch along the row, so tightening the spacing does not change the tier depth you need to build. The bench occupies 13 3/4 in of it closed and 16 1/2 in with the seat down, and the remainder is the circulation left between one row and the back of the next.

What is the platform actually made of?

Tubular iron reticular beams, assembled on site. The manufacturer describes the result as a light and fully demountable structure, with special joints designed for coupling the support uprights of the components that land on it — flooring and study bench alike. It stands on levelling feet whose rubber bases bring the whole deck true.

Who designed Blade System, and has it been recognized?

Dante Bonuccelli. The line received the Grand Design 2005 International Award in Milan, and in 2004 the Work & Emotion prize in the Intelligent Space category at Eimu, also in Milan. Both awards name Blade specifically rather than the manufacturer.

What are the working heights?

The writing surface sits 29 in from the floor and the seat 18 in, within an overall height of 32 1/4 in measured to the top of the bench. Those three figures are fixed by the system; what the project changes is spacing, tier geometry and finish, not the heights.

Routing power and data to a Blade System row

Cabling reaches the bench from below and surfaces only at the point of use. This is the path the manufacturer provides for, step by step.

Bring the service into the platform

The route begins under the floor. The raised platform is the technical space: beams are assembled on site and the cable run is laid within that volume, before the flooring panels go down.

Carry it up through the uprights

From the platform the cable rises toward the working surface through the support uprights anchored to the metal structure, which is also what makes the run invisible from the aisle.

Terminate under the surface

Sockets are positioned under the writing surface rather than on it. The system is arranged for both electrical and data connections, and the socket itself is supplied on demand, so the specification has to state what is being fitted.

Close the access cover

Each position is reached through an anodized aluminum cover on the desk. Closed, the surface reads as one plane; opened, it exposes the outlets without tools.

Leave the route reachable

Finish by confirming the flooring panels above the run are removable ones: the flooring is inspectable, which is what makes the cable reachable later without dismantling the benches.